1. Home
  2. Blog
  3. Temperatures & time limits

Temperatures & time limits

How to check a probe thermometer: the ice water and boiling water tests

The two calibration tests the SFBB pack asks for, the pass ranges, how often to do them, and the probe care habits that stop a good probe giving bad readings.

Every temperature record in your diary depends on one small piece of equipment telling the truth. A probe that reads two degrees high will pass a chicken that is not cooked, and nobody will know until someone is ill. The "Prove it" sheet in the SFBB pack for caterers says to check the probe regularly, for example once a month, for exactly this reason. It is one of the cheapest pieces of food safety you will ever do. Two glasses, two minutes.

The two tests

Pass ranges for the two calibration tests. The dark tick is the target; the green band is what counts as a pass. Source: FSA, Safer Food, Better Business for caterers: "Prove it"
View as a table
Probe calibration
TestExpectedPass rangeIf it fails
Iced water0°C-1°C to +1°CReplace or send for calibration
Boiling water100°C99°C to 101°CReplace or send for calibration

Iced water

  1. 1Fill a glass with crushed iceThen add just enough cold water to fill the gaps. It should be slush, mostly ice.
  2. 2Stir and waitAbout a minute, so the water reaches 0°C throughout.
  3. 3Insert the probeInto the middle of the slush, not touching the glass. Wait for the reading to settle.
  4. 4Read and recordBetween -1°C and +1°C is a pass. Write the date, reading and result.
The ice water test. The important detail is a proper slush of ice and water, not a glass of cold water with two cubes in it.

Boiling water

Bring a pan to a rolling boil, put the probe tip in the water without touching the pan, wait for the display to settle, and read it. 99°C to 101°C is a pass. Water boils at a slightly lower temperature at altitude, but nowhere in the UK is high enough for that to matter. Be careful with the steam.

You only need one of the tests to check the probe, and ice water is the safer one. Doing both tells you the probe is accurate across the range, which matters because a probe can be right at 0°C and wrong at 75°C.

Probe or infrared?

Digital probeInfrared
Core temperature of cooked foodYesNo
Reheating and hot holdingYesNo
Quick fridge surface spot checksPartlyYes
Reflective packagingYesNo
Needs cleaning between usesYesNo
Can be left in the ovenNoNo
Which thermometer for which job. An infrared gun is useful, but it is not a probe.

Probe care

A good probe gives bad readings when it is mistreated. The pack's care rules are short:

  • Clean and disinfect before and after every useProbe wipes, kept moist. A dirty probe is a cross-contamination route from raw to cooked.
  • Wait for the display to stop movingReading too early gives a low number.
  • Keep it away from heat and liquidsDo not leave it in the fridge, on the pass or in a pan.
  • Do not drop itA drop can knock the sensor out of calibration. Recheck after any knock.
  • Replace a low battery straight awayLow batteries cause drifting readings before the display dies.
  • Have a spareA kitchen with one probe and no spare has no probe the day it fails.

The probe check is opening check 8 in the daily diary ("probe thermometer is working and probe wipes are available"), so the daily version is a glance and the monthly version is the test above. Both are covered in the SFBB daily diary explained. For what you are probing for once you trust the number, see 70°C for 2 minutes explained.

Questions people ask

How often should a food probe be calibrated?

The SFBB pack says to check it regularly, for example once a month, and it is one of the questions in the 4-weekly review. Many kitchens do it weekly because it takes two minutes. Also do it after the probe is dropped, after a battery change, and whenever a reading looks wrong.

Can I calibrate a probe myself?

You can check it yourself with the ice water and boiling water tests. Most kitchen probes cannot be adjusted, so if it fails the check, replace it or send it to the manufacturer for calibration. A certificate from an accredited calibration is only needed if your own system or a customer requires it.

Can I use an infrared thermometer instead of a probe?

For surface spot checks in a fridge, yes. For cooking, reheating and hot holding, no. Infrared reads the surface, and the surface of a chicken thigh is not where the bacteria survive. You need a probe in the centre.

My probe reads 2°C in ice water. Is that a fail?

Yes. The pass range is -1°C to +1°C. A probe that is 2°C out will tell you a 68°C chicken is 70°C. Replace it.

Keep these checks without the folder

SafeTap turns the SFBB diary into a few taps a day: temperatures with instant pass or fail, photo proof, corrective actions and an Inspector Pack you can show or export. £15 per site per month after a 90-day free trial, no card needed to start.