Temperature log app
A temperature log that tells you when a reading is wrong
A paper sheet takes any number you write on it. SafeTap checks each fridge, freezer, hot holding, cooking and delivery reading against its target as you enter it, and shows pass or fail before you put the phone down.
£15 per site per month after the trial · No card to start · Works with the probe you have
The targets
What each reading is checked against
Two of these numbers are law. The others are FSA guidance. The app treats them all as targets and we label which is which, because an inspector will know the difference.
Fridge
8°C or below
Legal requirement in England, Wales and Northern Ireland.
The starter list has a fridge temperature check, and you can rename it to match your own kitchen. A walk-in is logged the same way as an under-counter unit.
Hot holding
63°C or above
Legal requirement in England, Wales and Northern Ireland.
Food can be below 63°C once, for up to 2 hours, for service or display. A low reading tells you to reheat now or chill within 2 hours.
Freezer
-18°C or below
FSA recommendation, not a legal limit.
A warm reading tells you to move the food and call an engineer, and asks which of those you did.
Cooking
70°C for 2 minutes
The FSA's standard cooking combination.
A core temperature check for the food you probe. Clean the probe with a wipe between foods.
Deliveries
Chilled items 8°C or below
Shown as a hint on the delivery screen.
You record the temperature on arrival and choose accept or reject. The app does not reject a delivery for you.
The reasoning behind each number is in our guides to fridge, freezer and hot holding temperatures and safe cooking temperatures.
When it goes wrong
What happens when a reading fails
Fridges fail. What matters afterwards is that someone noticed, did something about it, and wrote down what they did.
The reading is flagged
The record is marked out of range, with a line saying what to do. For a freezer that is "Freezer too warm (target: -18°C or below). Move food and call an engineer."
It asks what you did
You pick from a short list. For hot holding: reheated until steaming hot and returned to hot holding, chilled to 8°C or below for later service, or discarded.
Managers are told
Managers get a notification that a reading is out of range at that site. The reading and the action stay together in the record.
On inspection day
What the inspector sees
Open the Inspector Pack and choose the dates. It shows how many days have records, how many checks were done, and a list of issues with what was done about each one.
A manager can export the same range as a PDF: day by day, each reading with its time, the corrective actions, and any photos with their date and time. Readings are stamped by our server when they arrive. One taken with no signal keeps the phone's time and is sent when the phone reconnects.
Keep the probe honest too
A log is only as good as the thermometer. In iced water a probe should read between -1°C and +1°C, and in boiling water between 99°C and 101°C.
Before you sign up
What it does not do
If you are looking for wireless sensors that watch a cold room around the clock, this is a different kind of product.
- It is not a sensor system. Nothing is fitted inside your fridges and nothing is read automatically. A person takes each reading and enters it.
- It will not tell you a fridge failed overnight. You find out at the next check, the same as with a paper sheet.
- Reminders go out at opening and closing time. There is no reminder during service for hot holding or cooking checks.
- A photo of a fridge dial shows the check was done at that time. The app does not read the number in the photo.
- It runs on phones and tablets. There is no website login or desktop dashboard.
- It is built on Safer Food, Better Business, so the limits are those for England, Wales and Northern Ireland.
Price
£15 per site per month
Free for 90 days with no card. Then one monthly price per site, with no contract and no limit on how many readings you log.
Temperature logs are one part of the app. The same subscription covers the rest of the Safer Food, Better Business routine: see what else moves from the folder to the phone, or go straight to pricing.
Start with one fridge
Log tomorrow's opening temperatures in the app as well as on the sheet. Do it for a week and see which record has the gaps.
Start the free trialQuestions
About logging temperatures
How often should I record fridge temperatures?
The FSA's Safer Food, Better Business pack says to check the temperature of your fridges at least once a day, starting with your opening checks. Many kitchens also check at closing. SafeTap sends a reminder when opening checks are due, and the fridge reading is logged with them.
What temperature should a commercial fridge be in the UK?
Chilled food must be kept at 8°C or below. That is a legal requirement in England, Wales and Northern Ireland. Setting the fridge a few degrees colder gives you a margin when the door is opened often.
Is -18°C for a freezer a legal requirement?
No. It is the FSA's recommendation: the pack says frozen food should be kept at -18°C or below. The legal limits are 8°C for chilled food and 63°C for hot holding. SafeTap still checks freezer readings against -18°C because that is the figure to work to and to record.
Can I keep temperature records on a phone instead of paper?
Yes. You need records that show your food safety system is being followed, and the rules do not say they must be on paper. What counts is that they are complete and that you can show them on the day. SafeTap is not made, approved or endorsed by the Food Standards Agency or any council.
Does the app work inside a walk-in fridge with no signal?
Yes. The reading is saved on the phone and sent when the phone is back online. One thing to know: the question about what you did for an out-of-range reading appears once the record has reached our server, so it follows a moment later.
Do I need a special thermometer?
No. Use the probe you already have and type the reading in. SafeTap also has a Bluetooth probe link if you would rather not type. Either way, check the probe regularly: in iced water it should read between -1°C and +1°C, and in boiling water between 99°C and 101°C.
Create your account here, then download the app and sign in.